P165 GW (O) – 165kVA Perkins Generator

0 out of 5

STANDBY: 165kVA                PRIME: 150kVa

Perkins model P165 GW (O) with a prime power output of 150kVA, 120kW and standby output of 165kVA, 132kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 / 400/230 / 380/220 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1006TAG2, coupled to a Leroy Somer/Newage Stamford brushless alternator. 

Read more

P198 GW (C) – 200kVA Perkins Generator

0 out of 5

STANDBY: 198kVA                PRIME: 180kVa

Perkins model P198 GW (C) with a prime power output of 180kVA, 144kW and a standby output of 198kVA, 158kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1106 C-E66TAG4, coupled to a Leroy Somer/Newage Stamford brushless alternator. The complete generating set is mounted in a weatherproof and acoustic enclosure designed to reduce the noise level to within EU limits.

Read more

P198 GW (O) – 200kVA Perkins Generator

0 out of 5

STANDBY: 198kVA                PRIME: 180kVa

Perkins model P198 GW (O) with a prime power output of 180kVA, 144kW and a standby output of 198kVA, 158kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1106 C-E66TAG4, coupled to a Leroy Somer/Newage Stamford brushless alternator.

Read more

P22 GW (C) – 22kVA Perkins Generator

0 out of 5

STANDBY: 23kVA                PRIME: 20kVa

Perkins model P23 GW (C) with a prime power output of 20kVA, 16 kW and a standby output of 22kVA, 17.6 kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 / 400/230 / 380/220 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 404D-22G, coupled to a Leroy Somer/Newage Stamford brushless alternator. The complete generating set is mounted in a weatherproof and acoustic enclosure designed to reduce the noise level to within EU limits.

Read more

P22 GW (O) – 22kVA Perkins Generator

0 out of 5

STANDBY: 23kVA                PRIME: 20kVa 

Perkins model P23 GW (C) with a prime power output of 20kVA, 16 kW and a standby output of 22kVA, 17.6 kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 / 400/230 / 380/220 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 404D-22G, coupled to a Leroy Somer/Newage Stamford brushless alternator.

Read more

P220 GW (C) – 220kVA Perkins Generator

0 out of 5

STANDBY: 220kVA                PRIME: 200kVa

Perkins model P220 GW (C) with a prime power output of 200kVA, 160kW and a standby output of 220kVA, 176 kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 / 400/230 380/220 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1306C-E87TAG3, coupled to a Leroy Somer/Newage Stamford brushless alternator. The complete generating set is mounted in a weatherproof and acoustic enclosure designed to reduce the noise level to within EU limits.

Read more

P220 GW (O) – 220kVA Perkins Generator

0 out of 5

STANDBY: 220kVA                PRIME: 200kVa

Perkins model P220 GW (O) with a prime power output of 200kVA, 160kW and a standby output of 220kVA, 176 kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 / 400/230 380/220 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1306C-E87TAG3, coupled to a Leroy Somer/Newage Stamford brushless alternator.

Read more

P248 GW (O) – 250kVA Perkins Generator

0 out of 5

STANDBY: 248kVA                PRIME: 225kVa

Perkins model P248 GW (O) with a prime power output of 225kVA, 180kW and a standby output of 248kVA, 198 kW, at 0.8 power factor, 3 phase, 4 wire, 415/240 Volts, 50 Hz at 1500 RPM. The unit is powered by the Perkins diesel engine model 1306C-E87TAG4, coupled to a Leroy Somer/Newage Stamford brushless alternator. 

Read more